About us /  ABOUT   US
We are a veteran team in process analytical industry with decades’ years of accumulated rich product & application knowledge and experience in Emission monitoring, Hydrocarbon Process, Industrial Gas, Semiconductor, Power Generation, Iron & Steel and other market sectors in China. We offer total solution to our customers including analyzer, integrated system and service&maintenance.All of our key staffs have ever worked for multinational companies for many years before. We have a very high reputation in China market with track record performance since we ever helped one multinational gas analyzer company to grow their business 7 times within 7 years in China.Our primary business model is to help small to mid-size process analyzer manufacturers with excellent product and technologies to maximize their business potential and build up their brand awareness in China by leveraging our depth knowledge and rich application experience in process analytical industry as well as our e...
News / NEWS
Advanced Analyzers attends IE expo 2018 in Shanghai
The nineteenth China IE Expo was held in Shanghai New International Expo Center on 3-5 May 2018. More than 100 top experts from the Ministry of environmental protection, the national development and Reform Commission, the Ministry of water resources and other authoritative organizations, such as the Chinese Academy of Sciences, the China Institute of environmental research and other leading technical enterprises, participated in the Expo this year.AdvancedAnalyzers  participated in the exhibition as exhibitor this year.  We showed a variety of new products and new technologies to the visitors. Our on-site demonstration includes a wide range of portable pollution source monitoring instruments, atmospheric monitoring instruments, and VOC on-line monitoring instruments.Our booth in the IE ExpoThe booth was crowded with people interested in our products Mr Douglas Adkin from Defiant Technology joined the expo and took photos with Advancedanalyzers'  employees. ...
2018 - 07 - 03
Advanced Analyzers take part in the 16th China International Environmental Protection Exhibition
In June 7, 2018, the sixteenth China International Environmental Protection Exhibition (CIEPEC 2018) opened in Beijing at the China International Exhibition Center (Jingan Zhuang Pavilion).CIEPEC 2018 is sponsored by the China Environmental Protection Industry Association, the Ministry of ecological environment, the people's Government of Beijing, the China International Chamber of Commerce and the United Nations Environment Programme.There are more than 700 domestic and foreign exhibitors in this exhibition. Overseas from the United States, Britain, Italy, France, Japan, South Korea and other 17 countries and regions. Exhibitors are strong and full of skills. AdvancedAnalyzers joined this industry feast as exhibitor. AA's booth is located in Hall two.AA employees introduce our products to visitorsAA employee is demonstrating  our portable analyzer at the scene.Due to the exhibition's location is in the north, a large number of northern end users have got the opportunity to g...
2018 - 07 - 03
Products / PRODUCT
产品名称: Model 700 FTIR
产品特点: CAI offers three analyzer models that utilize Fourier Transfer Infrared technology for measuring concentrations of multiple gases within a sample. CAI FTIR analyzers deliver fast, accurate analysis of virtually any gas that has an infrared absorption spectrum.▪ FTIR Products Data Sheet▪ 700 FTIR – Most IR-absorbing gases at ppb and low-ppm levels▪ 700 FTIR Heated Sampler – For optimal hot/wet sample handling700 FTIR Heated SamplerCAI FTIR analyzers are based on Fourier Transform Infrared Spectroscopy. Non-symmetrical gas phase molecules absorb IR light, causing the molecular bonds to stretch, bend or rotate. This absorption is used to measure and quantify several chemical components simultaneously. CAI FTIR analyzers are well-suited for a wide range of applications, including:▪ Stack gases (CEM/MACT)▪ Vehicle emissions▪ Process control▪ VOC abatement/scrubber efficiency▪ Ammonia slip▪ Gas purity▪ Agricultural emissions▪ Greenhouse gas▪ Biomass/landfill gasFTIR Analyzer Highli...
产品名称: Model 700 FID
产品特点: CAI FID analyzers rely on the Flame Ionization Detection principle to measure the total concentration of hydrocarbons in a gas sample. The gas sample becomes ionized in the flame and the electrostatic field causes the charged particles to migrate, creating a small current that is measured by the amplifier. The current is directly proportional to the amount of hydrocarbon in the sample. The 700 MHFID model measures Total Hydrocarbon and provides a means of differentiating between Methane and non-Methane hydrocarbons.CAI FID analyzers can measure THC or CH4 in ppm or percent levels. They are ideal for applications such as:▪ VOC abatement/scrubber efficiency▪ Combustion engine testing▪ EPA Method 25A compliance monitoring▪ Continuous emission monitoring (CEMs)▪ Vehicle emissions▪ Fermentation monitoring▪ Carbon bed breakthrough detection▪ Process gas analysis
产品名称: Model 700 NDIR
产品特点: CAI offers two analyzer models that use Non-Dispersive Infrared (NDIR) technology to measure the concentrations of IR-absorbing gases in a sample. The 600 and ZRE models utilize paramagnetic or fuel cell technology to measure Oxygen. ▪ 700 NDIR/O2 – Up to 3 IR channels or 2 IR channels + O2▪ZRE NDIR/O2 – Up to 4 IR channels (including SO2, NOx) + O2CAI NDIR analyzers’ measurements are based on the infrared absorption characteristics of gases. Using a single infrared beam to measure gas concentrations, they deliver highly stable and reliable results. CAI NDIR analyzers are well-suited for a wide range of applications, including:▪ Stack gases (CEM)▪ Vehicle emissions▪ Combustion efficiency▪ Turbine/generator feedback control▪ Process chemical gas analysis▪ Fuel cell analysis▪ Personnel safety700 NDIR/O2 Analyzer Highlights▪ Accurate analysis of IR-absorbing gases▪ Measure from low ppm to 100% full scale▪ Rapid response time▪ Internal sample pump▪ Optional Model 600 P/F – O...
产品名称: Model 700 CLD
产品特点: CAI offers three analyzer models that utilize chemiluminescence technology for analyzing NO, NOx and NO2 concentrations within a gas sample.▪ 700 CLD - NOx, NO, NO2The chemiluminescence method is used to measure the reaction between ozone and nitric oxide. In the NOx mode, the sample is routed through a converter. The resultant reaction is directly proportional to the total concentration of NOx. The reliability and rapid response time of CAI CLD analyzers make them particularly well-suited for the following applications:▪ Continuous emissions monitoring (CEM)▪ Vehicle emissions▪ Scrubber efficiency▪ Combustion efficiency▪ Ammonia slip▪ Process control▪ Power plant de-nitrification▪ Fuel cell analysisCLD Analyzer Highlights▪ Measure NO/NOx from 0 to 3,000 ppm full scale▪ Rapid response time▪ No vacuum pump required▪ Lowest CO2 quench available▪ Low-temperature vitreous carbon NOx converter – no ammonia interference▪ Auto calibration and ranging▪ Electronic proportional pressur...
产品特点: For continuous source discharge and ambient air monitoringMeasurement methods are strictly followed with CEE UNI EN 13526 - UNI EN 12619 regulationsEasy to use and maintainSeparable methane partBuilt-in zero air supplyBuilt-in widescreen data loggerThe FID detector is a carbon atom counter. The sample was introduced into a micro-flame ignited by hydrogen and air (1:10 ratio), where the charge oxidized by Cx to CO is the proportional carbon content in the sample. The actual concentration is calculated from the calibration using the trace gas mixture. The charge is collected by two polarized electrodes and converted by the circuit to an electronic signal.Instrument DescriptionMod 2001 VOC analyzer's design, development and manufacturing is strictly in accordanced with the provisions of the European UNI EN 113526 - UNI EN 12619 to do. This rule is intended for the detection of VOC, THC and CH4 concentrations in emissions. During sampling, the sample is drawn through a probe with a ceramic...
产品特点: The Model 8807 is a portable VOCs analyzer based on the GC-FID principle. Both the sampling system and the analysis system are heated to a high temperature. THC and CH4 can be measured separately by column separation and backflushing techniques to calculate the total non-methane hydrocarbons NMHC. Analyzer built-in sampling diaphragm pump can be automatically injected. The instrument can adjust the chromatographic system and set up chromatographic software according to the need, measure the content of the specified kind of gas. Up to 8 specified gas components can be measured separately, except for the total methane. The Model 8807 offers the best solution for the portable detection of VOCs. Products are widely used in industrial sectors, environmental protection and scientific research fields: Emission monitoring Factory flue gas analysis Air quality testing Emergency monitoring Protective boundary detection ...Working Principle  The sample was filte...
产品特点: The FROG5000 applies an innovative MEMS microchromatography + detector modular structure that is powerful and easy to use. Various specified gas content of VOCs, benzene series, hydride, phosphorus, monument, etc. from the trace level ppb to the percentage concentration measurement can be done. FROG5000 is equipped with a rechargeable lithium battery, built-in memory card, special chromatography software, body and compact portable. Depending on the needs, different injection devices can be configured for measuring gas, liquid and solid samples, as well as an optional dilution unit. widely used in:· Environmental AnalysisIndustrial hygiene and safetyIndoor air quality monitoringProcess AnalysisLaboratory analysisPollution spot testWorking Principle:FROG5000 portable analyzer mainly contains chromatography, PID detector, injection device and auxiliary unit. The sample is sucked into the instrument via the sampling pump, and after the electronic pressure regulation and volume control...
产品特点: Based on the principle of GC-FID, the Model 529 is heated to a high temperature by the sampling system and the analysis system. THC and CH4 can be measured separately by column separation and backflushing techniques to calculate the NMHC of non-methane hydrocarbons. Analyzer built-in sampling diaphragm pump can be automatically injected. The instrument can adjust the chromatographic system and set up chromatographic software according to the need, measure the content of the specified kind of gas. Up to 8 specified gas components can be measured separately, except for the total methane. According to the need to configure the benzene series separation column, measuring benzene, toluene, xylene and other content. Working Principle:529 analyzer using GC-FID principle, hydrogen flame ion detector. After the sample gas enters the analyzer via the sample pump, the column is filled with PQS or a suitable material through a 10-way rotary valve and the methane fraction is separated. The sep...
            Copyright ©2005 - 2018 ADVANCEDANALYZERS